Monday 13 October 2014

Site to Site Communication issue



Symptom - Site to site communication not working between  two site

Cause - .req and .job token files are accidently deleted from the SMS\Inboxes\Scheduler.box\UID folder on the SMS site server

Resolution –
·         Use a text editor to create new token .req and .job files.
·         Use a text editor to create two empty text files named ZZZZZZZZ.job and ZZZZZZZZ.req
·         Restarted the service SMS_executive

·         Once the same was done we could see site to site communication working fine and data replication will start.